Vital Sign Monitors:


 
 

Features:

  • Compact Pulse Oximetry System for monitoring Oxygen Saturation (SpO2), Pulse Rate (BPM), Non-Invasive Blood Pressure (NIBP) and Temperature
  • Bright, High resolution LCD screen to display the pleth wave form as well as the SPO2 and Pulse Rate readiungs
  • Seperate bright LED displays for systolic, diastolic and mean Blood Pressure readings.
  • Printer facility for printing reports immediately
  • Accurate BP readings in less than 40 seconds
  • Nurse call facility that alerts the nurse station in case of emergency
  • 24 hour Patient Data storage and trend data
  • Patient data transfer to a computer
  • Software for patient data analysis (Optional)
  • Rechargable battery with internal charger
  • Monitors Adult, Pediatric Parents Weighing above 5 kg

Monitor Functional Specifications

Display

High resolution fluroscent backlight 240 X 64 LCD graphical screen for Pleth waveform, Spo2 and BPM readings

3-digit, bright 7-segment LED displays for NIBP readings

Language Options English
Indicator 7-waveform display
Alarm indicating light
External DC supply indicating light
QRS voice & voice alarming
Interface Measurement parameter cable interface
Power supply socket
Simulated signal output
(1V & 5V amplitude optional, tolerance <20%),
output impedance 50 ohm, signal delay <30ms.
Battery Chargeable up to 1 hour backup
TREND Time 1–72 hours
Recorder Optional 
Non- Inversive Blood Pressure

Technique Oscillometric
Measurement Range Systolic 40-260mmHg
Diastolic 20-200mmHg
Pulse 40-200BPM
Accuracy 3mmHg
 
Physical Dimensions

Dimensions 202W x 262H x 110D (mm)
Weight 3.4 kg
 
Enviornmental Conditions

Atmospheric Pressure 760mmHg
Humidity 5 to 95%( non condensing)
Operating Temp 0 - 40C
Storage / Transport Temp Dual-channel
No. of Channels 1 channel, dispalying 1 TEMP value


 

   
Electrical Ratings

AC Voltage 100–230V AC, 50 / 60 Hz
Battery Type Rechargable Internal Battery 12V
Battery Minimum Run Time

2 hours in power save mode, no printing and NIBP running at 90min interval; using new fully charged battery

SpO2

Measurement & Alarm Range 0–100%
Resolution: 1%
Precision: ±2% (70–100%), ±3% (60–70%), Not specified (below 60%)
PR & Alarm Range 0–254 bpm
Resolution: 1bpm
Precision: ±1%
   
   
 
Model 960P Vital Signs Monitor Brochure

Brochure

English (200K)
French (127K)
German (136K)
Italian (124K)
Portuguese (124K)
Spanish (124K)

Manual

English (3Mb)
French (2.7Mb)
German (3Mb)
Portuguese (3.4Mb)
Spanish (3.4Mb)